SCTE 104/35 Codex

SCTE 104

alternate_break_duration_data

insert_alternate_break_duration_data · Decimal

A 32-bit alternate break length in milliseconds that replaces the break_duration of the associated SCTE 35 splice_info_section. Zero leaves the original break_duration in place, and it is ignored except for spliceStart_normal and spliceStart_immediate. Added in SCTE 104 2022.

Clause citations