SCTE 104/35 Codex

SCTE 104

pre_roll_time

splice_request_data · Decimal

How far ahead of the splice point the event should fire, in milliseconds. It applies only to spliceStart_normal and spliceEnd_normal, and the minimum non-zero value this interface allows is 4000 milliseconds.

Clause citations